Journal Description
Micromachines
Micromachines
is a peer-reviewed, open access journal on the science and technology of small structures, devices and systems, published monthly online by MDPI.
- Open Access— free for readers, with article processing charges (APC) paid by authors or their institutions.
- High Visibility: indexed within Scopus, SCIE (Web of Science), PubMed, PMC, Ei Compendex, dblp, and other databases.
- Journal Rank: JCR - Q2 (Chemistry, Analytical) / CiteScore - Q2 (Mechanical Engineering)
- Rapid Publication: manuscripts are peer-reviewed and a first decision is provided to authors approximately 16.1 days after submission; acceptance to publication is undertaken in 1.9 days (median values for papers published in this journal in the second half of 2023).
- Recognition of Reviewers: reviewers who provide timely, thorough peer-review reports receive vouchers entitling them to a discount on the APC of their next publication in any MDPI journal, in appreciation of the work done.
- Testimonials: See what our editors and authors say about Micromachines.
Impact Factor:
3.4 (2022);
5-Year Impact Factor:
3.3 (2022)
Latest Articles
High-Dynamic-Range Integrated NV Magnetometers
Micromachines 2024, 15(5), 662; https://doi.org/10.3390/mi15050662 (registering DOI) - 18 May 2024
Abstract
High-dynamic-range integrated magnetometers demonstrate extensive potential applications in fields involving complex and changing magnetic fields. Among them, Diamond Nitrogen Vacancy Color Core Magnetometer has outstanding performance in wide-range and high-precision magnetic field measurement based on its inherent high spatial resolution, high sensitivity and
[...] Read more.
High-dynamic-range integrated magnetometers demonstrate extensive potential applications in fields involving complex and changing magnetic fields. Among them, Diamond Nitrogen Vacancy Color Core Magnetometer has outstanding performance in wide-range and high-precision magnetic field measurement based on its inherent high spatial resolution, high sensitivity and other characteristics. Therefore, an innovative frequency-tracking scheme is proposed in this study, which continuously monitors the resonant frequency shift of the NV color center induced by a time-varying magnetic field and feeds it back to the microwave source. This scheme successfully expands the dynamic range to 6.4 mT, approximately 34 times the intrinsic dynamic range of the diamond nitrogen-vacancy (NV) center. Additionally, it achieves efficient detection of rapidly changing magnetic field signals at a rate of 0.038 T/s.
Full article
(This article belongs to the Special Issue Accelerometer and Magnetometer: From Fundamentals to Applications, 2nd Edition)
Open AccessArticle
An Improved Method to Compute the Mutual Capacitance between Interdigital Transducers in Radio Frequency Surface Acoustic Wave Filters
by
Yali Zou, Xinyu Yang, Ping Luo and Yuhao Liu
Micromachines 2024, 15(5), 661; https://doi.org/10.3390/mi15050661 (registering DOI) - 18 May 2024
Abstract
This paper proposes an improved method to calculate the mutual capacitance between interdigital transducer (IDT) electrodes to enhance the accuracy of the traditional coupling-of-modes (COM) model, which is commonly used to simulate surface acoustic wave (SAW) filters and duplexers. In this method, the
[...] Read more.
This paper proposes an improved method to calculate the mutual capacitance between interdigital transducer (IDT) electrodes to enhance the accuracy of the traditional coupling-of-modes (COM) model, which is commonly used to simulate surface acoustic wave (SAW) filters and duplexers. In this method, the boundary element method (BEM) is adopted to obtain the capacitance per unit length in a layered medium, while the partial capacitance (PC) method is used to derive the effective relative permittivity of the multi-layered IDT. Numerical results from commercially available software are provided for comparison with the results calculated using the proposed method. The consistent results verify the validity and accuracy of this method, which also demonstrates significantly faster calculation speed compared to commercially available software. Precise electrical response prediction of a dual-mode SAW (DMS) filter can be achieved by applying this method to the COM model, and this ultra-fast calculation method can also be included in filter design optimization.
Full article
Open AccessArticle
Development of a Measurement Device for Micro Gas Flowrate Based on Laminar Flow Element with Micro-Curved Surface
by
Zixuan Wang, Ya Xu, Tiejun Liu, Zhenwei Huang and Dailiang Xie
Micromachines 2024, 15(5), 660; https://doi.org/10.3390/mi15050660 - 17 May 2024
Abstract
The laminar flow meter (LFM) boasts several advantages such as no moving parts, a wide range ratio, high measurement accuracy, quick dynamic response, etc., and is a promising technology for micro gas flow measurement. In order to explore the influence of different curvature
[...] Read more.
The laminar flow meter (LFM) boasts several advantages such as no moving parts, a wide range ratio, high measurement accuracy, quick dynamic response, etc., and is a promising technology for micro gas flow measurement. In order to explore the influence of different curvature radii on curved surface gap LFM, three curved structures with different curvature radii were designed. The computational fluid dynamics method is applied to simulate the flow feature of three structures. The simulated velocity cloud and pressure distribution show that the larger the curvature radius, the more stable the flow of gas medium. The relationship between differential pressure and volume flow was obtained through the test within a flow range of 0~540 sccm. Regression analysis revealed that the volume flow measured by the curved surface LFM had a high linear relationship with the differential pressure. Experimental findings indicate that differential pressure of the structure with a curvature radius of 2 mm was greater than that of other two structures (curvature radius of 6 mm and 3 mm) at the same point. This indicates that adding the number of surfaces can effectively increase the pressure loss, so as to obtain a larger range ratio, but will increase the measurement error.
Full article
Open AccessArticle
An Intelligent Non-Invasive Blood Pressure Monitoring System Based on a Novel Polyvinylidene Fluoride Piezoelectric Thin Film
by
Shilin Li, Taoyun Zhou, Muzhou Liu, Qiaomei Zhao and Yi Liu
Micromachines 2024, 15(5), 659; https://doi.org/10.3390/mi15050659 - 17 May 2024
Abstract
Hypertension is a common cause of cardiovascular diseases, closely associated with the high mortality and disability rates of cardiovascular diseases such as stroke and coronary heart disease. Therefore, developing a comfortable and sustainable device for monitoring human pulse signals holds practical significance for
[...] Read more.
Hypertension is a common cause of cardiovascular diseases, closely associated with the high mortality and disability rates of cardiovascular diseases such as stroke and coronary heart disease. Therefore, developing a comfortable and sustainable device for monitoring human pulse signals holds practical significance for the prevention and treatment of hypertension and cardiovascular diseases. PVDF flexible pressure sensors possess the characteristics of high sensitivity, good flexibility, and strong biocompatibility, thereby demonstrating extensive application potential in areas such as health monitoring, wearable devices, and electronic skins. This paper focuses on the development of a modified piezoelectric polymer and its application in an intelligent blood pressure monitoring system, demonstrating its outstanding performance and feasibility through a series of experiments. This research provides innovative material choices for the development of intelligent medical devices and offers beneficial guidance for the design and application of future intelligent health monitoring systems.
Full article
(This article belongs to the Special Issue Methodology, Microfabrication and Applications of Advanced Sensing and Smart Systems)
►▼
Show Figures
Figure 1
Open AccessArticle
A Study on the Frequency-Domain Black-Box Modeling Method for the Nonlinear Behavioral Level Conduction Immunity of Integrated Circuits Based on X-Parameter Theory
by
Xi Chen, Shuguo Xie, Mengyuan Wei and Yan Yang
Micromachines 2024, 15(5), 658; https://doi.org/10.3390/mi15050658 - 17 May 2024
Abstract
During circuit conduction immunity simulation assessments, the existing black-box modeling methods for chips generally involve the use of time-domain-based modeling methods or ICIM-CI binary decision models, which can provide approximate immunity assessments but require a high number of tests to be performed when
[...] Read more.
During circuit conduction immunity simulation assessments, the existing black-box modeling methods for chips generally involve the use of time-domain-based modeling methods or ICIM-CI binary decision models, which can provide approximate immunity assessments but require a high number of tests to be performed when carrying out broadband immunity assessments, as well as having a long modeling time and demonstrating poor reproducibility and insufficient accuracy in capturing the complex electromagnetic response in the frequency domain. To address these issues, in this paper, we propose a novel frequency-domain broadband model (Sensi-Freq-Model) of IC conduction susceptibility that accurately quantifies the conduction immunity of components in the frequency domain and builds a model of the IC based on the quantized data. The method provides high fitting accuracy in the frequency domain, which significantly improves the accuracy of circuit broadband design. The generated model retains as much information within the frequency-domain broadband as possible and reduces the need to rebuild the model under changing electromagnetic environments, thereby enhancing the portability and repeatability of the model. The ability to reduce the modeling time of the chip greatly improves modeling efficiency and circuit design. The results of this study show that the “Sensi-Freq-Model” reduces the broadband modeling time by about 90% compared to the traditional ICIM-CI method and improves the normalized mean square error (NMSE) by 18.5 dB.
Full article
(This article belongs to the Special Issue Latest Advancements in Semiconductor Materials, Devices, and Systems)
►▼
Show Figures
Figure 1
Open AccessArticle
Design of Miniaturized 90-Degree Hybrid Coupler with Wide Rejection Band Using Neural Network
by
Golshan Mohamadpour, Salman Karimi and Saeed Roshani
Micromachines 2024, 15(5), 657; https://doi.org/10.3390/mi15050657 - 17 May 2024
Abstract
In this paper, a 3 dB 90-degree hybrid coupler with size reduction and harmonics rejection was designed. In the proposed coupler structure, four simple low-pass filters (LPFs) were applied. An artificial neural network (ANN) was used to determine the dimensions of the applied
[...] Read more.
In this paper, a 3 dB 90-degree hybrid coupler with size reduction and harmonics rejection was designed. In the proposed coupler structure, four simple low-pass filters (LPFs) were applied. An artificial neural network (ANN) was used to determine the dimensions of the applied LPFs based on EM simulation data. The applied ANN model could also provide the desired LPF parameters, including the cut-off frequency (fc), bandwidth (BW), and insertion loss (IL). Designing an applied LPF involves complex mathematical calculations and simulations to optimize parameters. However, by utilizing neural networks, the design process can be significantly streamlined and automated. Neural networks have the ability to learn complex patterns and relationships within data, making them well suited for optimizing the performance of applied components. The proposed 90-degree hybrid coupler works correctly at 1800 MHz and has a small size of 16.6 mm × 15.15 mm, which provides a 73% size reduction compared to a normal 1800 MHz coupler. The designed coupler not only decreases the circuit size but also provides a wide rejection band from 4.8 GHz to 11.2 GHz, which suppresses the second to sixth harmonics. The insertion loss parameter of this 90-degree hybrid coupler is less than 0.1 dB at the working frequency, which shows the superior performance of the proposed coupler.
Full article
(This article belongs to the Special Issue Advances in Sensors and Electronic Instrumentation 2024)
►▼
Show Figures
Figure 1
Open AccessArticle
Passive Wireless Partial Discharge Sensors with Multiple Resonances
by
Zhenheng Xu, Bing Tian, Shiqi Guo, Qingan Huang, Lifeng Wang and Lei Dong
Micromachines 2024, 15(5), 656; https://doi.org/10.3390/mi15050656 - 17 May 2024
Abstract
Partial discharge (PD) is the dominant insulating defect in Gas-Insulated Switchgear (GIS). The existing detection methods are mainly divided into built-in wire-connected disk antennas with destructive drilling and external ultra-high frequency antennas with poor anti-interference ability. This research introduces a passive wireless PD
[...] Read more.
Partial discharge (PD) is the dominant insulating defect in Gas-Insulated Switchgear (GIS). The existing detection methods are mainly divided into built-in wire-connected disk antennas with destructive drilling and external ultra-high frequency antennas with poor anti-interference ability. This research introduces a passive wireless PD sensor implanted inside GIS on the observation window. The sensor is implemented by a sheeting branch-inductor with multiple resonances which is able to enhance detection sensitivity. A coaxially aligned readout circuit, positioned outside the GIS, interrogates the PD sensor to wirelessly obtain the PD signal. The proposed sensing scheme improves signal-to-noise ratio and ensures minimal disruption to the electric field distribution inside GIS. An experimental setup was established in a controlled laboratory environment to benchmark the multi-resonant sensor against the commercial UHF sensor. A 2.5-times enhancement of signal strength was observed. Since our sensor was implanted inside the GIS, a high signal-to-noise ratio (68.82 dB) was obtained. Moreover, we constructed a wireless calibration test to investigate the accuracy of the proposed sensor. The precision of the signal test was as high as 0.72 pC. The pulse phase distribution information was collected to demonstrate a phase-resolved partial discharge (PRPD) pattern. The experiment results validate the effectiveness of the proposed method and demonstrate excellent performance in PD detection.
Full article
(This article belongs to the Section E:Engineering and Technology)
►▼
Show Figures
Figure 1
Open AccessArticle
Fly-Cutting Processing of Micro-Triangular Pyramid Arrays and Synchronous Micro-Scrap Removal
by
Jiashun Gao, Zhilong Xu, Yu Lei and Su Huang
Micromachines 2024, 15(5), 655; https://doi.org/10.3390/mi15050655 - 16 May 2024
Abstract
►▼
Show Figures
Many micro-scraps are generated when a micro-triangular pyramid array (MTPA) is machined by the fly-cutting method. Micro-scraps are generally not removed quickly enough; therefore, these residual micro-scraps participate in the cutting process again, scratching the workpiece surface and accelerating diamond tool wear. To
[...] Read more.
Many micro-scraps are generated when a micro-triangular pyramid array (MTPA) is machined by the fly-cutting method. Micro-scraps are generally not removed quickly enough; therefore, these residual micro-scraps participate in the cutting process again, scratching the workpiece surface and accelerating diamond tool wear. To remove micro-scraps rapidly, a fly-cutting method to produce MTPAs on vertically oriented working surfaces was developed during this study. The results show that an MTPA produced by fly cutting on a vertical workpiece had a clearly outlined structure, high dimensional accuracy, and a low surface roughness. There was no micro-scrap residue on the workpiece surface and the diamond tool wear was small. The cutting inlet edges had no burrs, and the cutting outlet edges had only a small number of burrs. This method of fly cutting MTPAs on vertically oriented working surfaces provides a foundation for the development of high-precision micro-triangular pyramid optical elements.
Full article
Figure 1
Open AccessArticle
Research on the Influence of the Material Removal Profile of a Spherical Polishing Tool on the Mid-Spatial Frequency Errors of Optical Surfaces
by
Zhaohao He, Kuo Hai, Kailong Li, Jiahao Yu, Lingwei Wu, Lin Zhang, Xing Su, Lisheng Cai, Wen Huang and Wei Hang
Micromachines 2024, 15(5), 654; https://doi.org/10.3390/mi15050654 - 15 May 2024
Abstract
Elastic spherical polishing tools effectively conform to the polishing surface and exhibit high efficiency in the removal of materials, so they are extensively used in the sub-aperture polishing stages of optical components. However, their processing is often accompanied by significant mid-spatial frequency (MSF)
[...] Read more.
Elastic spherical polishing tools effectively conform to the polishing surface and exhibit high efficiency in the removal of materials, so they are extensively used in the sub-aperture polishing stages of optical components. However, their processing is often accompanied by significant mid-spatial frequency (MSF) errors, which critically degrade the performance of optical systems. To suppress the MSF errors generated during polishing with spherical tools, this study investigates the influence factor of MSF errors during the polishing process through an analysis of the convolution effect in material removal. A material removal profile model is established, and a uniform removal simulation is conducted to assess the influence of different shape material removal profiles on MSF errors. Simulation and experimental results show that a Gaussian-like shape material removal profile is more effective in suppressing the MSF errors during polishing compared to the “W” and trapezoidal shape material removal profiles. In addition, based on the characteristics of the RMS decreasing in a serrated trend with the decrease in path spacing, a path spacing optimization method considering the polishing efficiency is proposed to improve the polishing efficiency while controlling the MSF errors, and the effectiveness of the path spacing optimization method is verified by comparing the MSF error at the maximum theoretical path spacing and the path spacing that is less than this. Finally, the path spacing optimization method is used to polish single-crystal silicon to further illustrate its practicality.
Full article
(This article belongs to the Special Issue Precision Optical Manufacturing and Processing)
Open AccessArticle
Rapid and Sensitive Detection by Combining Electric Field Effects and Surface Plasmon Resonance: A Theoretical Study
by
Qijie Qiu and Yan Xu
Micromachines 2024, 15(5), 653; https://doi.org/10.3390/mi15050653 - 15 May 2024
Abstract
Surface plasmon resonance (SPR) has been extensively employed in biological sensing, environmental detection, as well as chemical industry. Nevertheless, the performance possessed by conventional surface plasmon resonance (SPR) biosensors can be further limited by the transport of analyte molecules to the sensing surface,
[...] Read more.
Surface plasmon resonance (SPR) has been extensively employed in biological sensing, environmental detection, as well as chemical industry. Nevertheless, the performance possessed by conventional surface plasmon resonance (SPR) biosensors can be further limited by the transport of analyte molecules to the sensing surface, noteworthily when small molecules or low levels of substances are being detected. In this study, a rapid and highly sensitive SPR biosensor is introduced to enhance the ability of the target analytes’ collection by integrating AC electroosmosis (ACEO) and dielectrophoresis (DEP). Both the above-mentioned phenomena principally arise from the generation of the AC electric fields. This generation can be tailored by shaping the interdigitated electrodes (IDEs) that also serve as the SPR biomarker sensing area. The effects exerted by different parameters (e.g., the frequency and voltage of the AC electric field as well as microelectrode structures) are considered in the iSPR (interdigitated SPR) biosensor operation, and the iSPR biosensors are optimized with the sensitivity. The results of this study confirm that the iSPR can efficiently concentrate small molecules into the SPR sensing area, such that SPR reactions achieve an order of magnitude increase, and the detection time is shortened. The rapid and sensitive sensor takes on critical significance in the development of on-site diagnostics in a wide variety of human and animal health applications.
Full article
(This article belongs to the Special Issue Micromachines for Dielectrophoresis, 3rd Edition)
►▼
Show Figures
Figure 1
Open AccessArticle
Synthesis of Submicron CaCO3 Particles in 3D-Printed Microfluidic Chips Supporting Advection and Diffusion Mixing
by
Ivan Reznik, Ekaterina Kolesova, Anna Pestereva, Konstantin Baranov, Yury Osin, Kirill Bogdanov, Jacobus Swart, Stanislav Moshkalev and Anna Orlova
Micromachines 2024, 15(5), 652; https://doi.org/10.3390/mi15050652 - 15 May 2024
Abstract
Microfluidic technology provides a solution to the challenge of continuous CaCO3 particle synthesis. In this study, we utilized a 3D-printed microfluidic chip to synthesize CaCO3 micro- and nanoparticles in vaterite form. Our primary focus was on investigating a continuous one-phase synthesis
[...] Read more.
Microfluidic technology provides a solution to the challenge of continuous CaCO3 particle synthesis. In this study, we utilized a 3D-printed microfluidic chip to synthesize CaCO3 micro- and nanoparticles in vaterite form. Our primary focus was on investigating a continuous one-phase synthesis method tailored for the crystallization of these particles. By employing a combination of confocal and scanning electron microscopy, along with Raman spectroscopy, we were able to thoroughly evaluate the synthesis efficiency. This evaluation included aspects such as particle size distribution, morphology, and polymorph composition. The results unveiled the existence of two distinct synthesis regimes within the 3D-printed microfluidic chips, which featured a channel cross-section of 2 mm2. In the first regime, which was characterized by chaotic advection, particles with an average diameter of around 2 m were produced, thereby displaying a broad size distribution. Conversely, the second regime, marked by diffusion mixing, led to the synthesis of submicron particles (approximately 800–900 nm in diameter) and even nanosized particles (70–80 nm). This research significantly contributes valuable insights to both the understanding and optimization of microfluidic synthesis processes, particularly in achieving the controlled production of submicron and nanoscale particles.
Full article
(This article belongs to the Special Issue Microfluidics and 3D Printing for Biomedical Applications)
►▼
Show Figures
Figure 1
Open AccessArticle
Development of Wearable Textile MIMO Antenna for Sub-6 GHz Band New Radio 5G Applications
by
Pendli Pradeep, Mohammed Mahaboob Basha, Srinivasulu Gundala and Javed Syed
Micromachines 2024, 15(5), 651; https://doi.org/10.3390/mi15050651 - 15 May 2024
Abstract
In this paper, an irregular octagonal two-port MIMO patch antenna is designed specifically for New Radio (NR) 5G applications in the mid-band sub-6 GHz. The proposed antenna comprises an irregularly shaped patch antenna equipped with a regular 50-ohm feed line and a parasitic
[...] Read more.
In this paper, an irregular octagonal two-port MIMO patch antenna is designed specifically for New Radio (NR) 5G applications in the mid-band sub-6 GHz. The proposed antenna comprises an irregularly shaped patch antenna equipped with a regular 50-ohm feed line and a parasitic strip line antenna, and is partially grounded. Jeans material serves as a substrate with an effective dielectric constant of 1.6 and a thickness of 1 mm. This material is studied experimentally. The proposed antenna design undergoes analysis and optimization using the ANSYS HFSS tool. Furthermore, the design incorporates the influence of the slot on both the ground plane and the parasitic strip line to optimize performance, enhance isolation, and improve impedance matching among antenna elements. The dimensions of the jeans substrate are 40 mm × 50 mm. The simulated impedance bandwidth ranged from 3.6 GHz to 7 GHz and the measured bandwidth was slightly narrower, from 4.35 GHz to 7 GHz. The simulation results demonstrated an isolation level greater than 12 dB between antenna elements, while the measured results reached 28.5 dB, and the peak gain for this proposed antenna stood at 6.74 dB. These qualities made this proposed antenna suitable for various New Radio mid-band 5G wireless applications within the sub-6 GHz band, such as N79, Wi-Fi-5/6, V2X, and DSRC applications.
Full article
(This article belongs to the Special Issue Recent Advances in Microwave Components and Devices, 2nd Edition)
►▼
Show Figures
Figure 1
Open AccessArticle
Carbon Nanotube-Based Printed All-Organic Microelectrode Arrays for Neural Stimulation and Recording
by
Tatsuya Murakami, Naoki Yada and Shotaro Yoshida
Micromachines 2024, 15(5), 650; https://doi.org/10.3390/mi15050650 - 14 May 2024
Abstract
In this paper, we report a low-cost printing process of carbon nanotube (CNT)-based, all-organic microelectrode arrays (MEAs) suitable for in vitro neural stimulation and recording. Conventional MEAs have been mainly composed of expensive metals and manufactured through high-cost and complex lithographic processes, which
[...] Read more.
In this paper, we report a low-cost printing process of carbon nanotube (CNT)-based, all-organic microelectrode arrays (MEAs) suitable for in vitro neural stimulation and recording. Conventional MEAs have been mainly composed of expensive metals and manufactured through high-cost and complex lithographic processes, which have limited their accessibility for neuroscience experiments and their application in various studies. Here, we demonstrate a printing-based fabrication method for microelectrodes using organic CNT/paraffin ink, coupled with the deposition of an insulating layer featuring single-cell-sized sensing apertures. The simple microfabrication processes utilizing the economic and readily available ink offer potential for cost reduction and improved accessibility of MEAs. Biocompatibility of the fabricated microelectrode was suggested through a live/dead assay of cultured neural cells, and its large electric double layer capacitance was revealed by cyclic voltammetry that was crucial for preventing cytotoxic electrolysis during electric neural stimulation. Furthermore, the electrode exhibited sufficiently low electric impedance of 2.49 Ω·cm2 for high signal-to-noise ratio neural recording, and successfully captured model electric waves in physiological saline solution. These results suggest the easily producible and low-cost printed all-organic microelectrodes are available for neural stimulation and recording, and we believe that they can expand the application of MEA in various neuroscience research.
Full article
(This article belongs to the Special Issue Selected Papers from the 14th Symposium on Micro-Nano Science and Technology on Micromachines)
►▼
Show Figures
Figure 1
Open AccessArticle
Broadening Bandwidth in a Semi-Active Vibration Absorption System Utilizing Stacked Polyvinyl Chloride Gel Actuators
by
Zhuoyuan Li, Chen Liu, Meiping Sheng, Minqing Wang, Hualing Chen, Bo Li and Peng Xia
Micromachines 2024, 15(5), 649; https://doi.org/10.3390/mi15050649 - 14 May 2024
Abstract
Plasticized polyvinyl chloride (PVC) gel is a new soft and smart material, whose potential in electroactive variable stiffness can be used for vibration control in soft robotic systems. In this paper, a new semi-active vibration absorber is developed by stacking PVC gel actuator
[...] Read more.
Plasticized polyvinyl chloride (PVC) gel is a new soft and smart material, whose potential in electroactive variable stiffness can be used for vibration control in soft robotic systems. In this paper, a new semi-active vibration absorber is developed by stacking PVC gel actuator units. The absorption bandwidth of a single PVC gel absorber covers the range of three natural frequencies (76.5 Hz, 95 Hz, 124 Hz) of a rectangular steel plate in vibration attenuation. The maximum reduction percentage in acceleration amplitude is 63%. With stacked PVC gel actuator units, the absorption bandwidth can be shifted and obviously broadened.
Full article
(This article belongs to the Special Issue Soft Actuators: Design, Fabrication and Applications)
►▼
Show Figures
Figure 1
Open AccessArticle
Modeling and Reliability Analysis of MEMS Gyroscope Rotor Parameters under Vibrational Stress
by
Lei Wang, Yuehong Pan, Kai Li, Lilong He, Qingyi Wang and Weidong Wang
Micromachines 2024, 15(5), 648; https://doi.org/10.3390/mi15050648 - 14 May 2024
Abstract
►▼
Show Figures
Vibrational environments can cause drift or changes in Micro-Electro-Mechanical System (MEMS) gyroscope rotor parameters, potentially impacting their performance. To improve the effective use of MEMS gyroscopes, this study introduced a method for evaluating the reliability of parameter degradation under vibration. We analyzed the
[...] Read more.
Vibrational environments can cause drift or changes in Micro-Electro-Mechanical System (MEMS) gyroscope rotor parameters, potentially impacting their performance. To improve the effective use of MEMS gyroscopes, this study introduced a method for evaluating the reliability of parameter degradation under vibration. We analyzed the working principle of MEMS gyroscope rotors and investigated how vibration affects their parameters. Focusing on zero bias and scale factor as key performance indicators, we developed an accelerated degradation model using the distributional assumption method. We then collected degradation data for these parameters under various vibration conditions. Using the Copula function, we established a reliability assessment approach to evaluate the degradation of the MEMS gyroscope rotor’s zero bias and scale factor under vibration, enabling the determination of reliability for these parameters. Experimental findings confirmed that increasing stress levels lead to reduced failure times and increased failure rates for MEMS gyroscope rotors, with significant changes observed in the zero bias parameter. Our evaluation method effectively characterizes changes in the reliability of the MEMS gyroscope rotor’s scale factor and zero bias over time, providing valuable information for practical applications of MEMS gyroscopes.
Full article
Figure 1
Open AccessArticle
Integrative BNN-LHS Surrogate Modeling and Thermo-Mechanical-EM Analysis for Enhanced Characterization of High-Frequency Low-Pass Filters in COMSOL
by
Jorge Davalos-Guzman, Jose L. Chavez-Hurtado and Zabdiel Brito-Brito
Micromachines 2024, 15(5), 647; https://doi.org/10.3390/mi15050647 - 13 May 2024
Abstract
This paper pioneers a novel approach in electromagnetic (EM) system analysis by synergistically combining Bayesian Neural Networks (BNNs) informed by Latin Hypercube Sampling (LHS) with advanced thermal–mechanical surrogate modeling within COMSOL simulations for high-frequency low-pass filter modeling. Our methodology transcends traditional EM characterization
[...] Read more.
This paper pioneers a novel approach in electromagnetic (EM) system analysis by synergistically combining Bayesian Neural Networks (BNNs) informed by Latin Hypercube Sampling (LHS) with advanced thermal–mechanical surrogate modeling within COMSOL simulations for high-frequency low-pass filter modeling. Our methodology transcends traditional EM characterization by integrating physical dimension variability, thermal effects, mechanical deformation, and real-world operational conditions, thereby achieving a significant leap in predictive modeling fidelity. Through rigorous evaluation using Mean Squared Error (MSE), Maximum Learning Error (MLE), and Maximum Test Error (MTE) metrics, as well as comprehensive validation on unseen data, the model’s robustness and generalization capability is demonstrated. This research challenges conventional methods, offering a nuanced understanding of multiphysical phenomena to enhance reliability and resilience in electronic component design and optimization. The integration of thermal variables alongside dimensional parameters marks a novel paradigm in filter performance analysis, significantly improving simulation accuracy. Our findings not only contribute to the body of knowledge in EM diagnostics and complex-environment analysis but also pave the way for future investigations into the fusion of machine learning with computational physics, promising transformative impacts across various applications, from telecommunications to medical devices.
Full article
(This article belongs to the Special Issue Selected Papers from the 20th SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC 2023))
►▼
Show Figures
Figure 1
Open AccessArticle
Evaluation of Phototoxicity of Short-Wavelength Laser Light Utilizing PCNA Accumulation
by
Tetsuya Matsuyama, Noboru Osaka, Mikiya Yamaguchi, Naohiro Kanamaru, Kenji Wada, Ai Kawakita, Kaori Murata, Kenji Sugimoto and Koichi Okamoto
Micromachines 2024, 15(5), 646; https://doi.org/10.3390/mi15050646 - 13 May 2024
Abstract
In recent years, diseases such as age-related macular degeneration and retinal pigment degeneration caused by excessive exposure to short-wavelength visible light have become significant concerns. With the aim of quantitatively evaluating the toxicity of short-wavelength light, proliferating cell nuclear antigen (PCNA) accumulation at
[...] Read more.
In recent years, diseases such as age-related macular degeneration and retinal pigment degeneration caused by excessive exposure to short-wavelength visible light have become significant concerns. With the aim of quantitatively evaluating the toxicity of short-wavelength light, proliferating cell nuclear antigen (PCNA) accumulation at the irradiation site was investigated using live cell imaging techniques to irradiate individual living cells with short-wavelength laser light. By examining the dependency of PCNA accumulation on the irradiation site within the cells and their cell cycle, it was observed that PCNA accumulation occurred only when the cell nucleus of cells in the S phase of the cell cycle was irradiated. We investigated the accumulation of PCNA at the laser irradiation site using laser light at wavelengths of 405 nm and 375 nm, with intensities ranging from 0.5 μW to 9.0 μW. The results confirmed an increase in PCNA accumulation with increasing intensity, and a higher accumulation was observed with laser light irradiation at a wavelength of 375 nm compared to 405 nm. By comparing the PCNA accumulation and 24 h cell viability, we demonstrated the feasibility of quantitatively assessing laser light toxicity through the measurement of PCNA accumulation.
Full article
(This article belongs to the Special Issue Ultraviolet Devices and Ultraviolet Germicidal Irradiation)
►▼
Show Figures
Figure 1
Open AccessArticle
Miniaturized and High Volumetric Energy Density Power Supply Device Based on a Broad-Frequency Vibration Driven Triboelectric Nanogenerator
by
Liting Wu, Zewei Ren, Yanjun Wang, Yumin Tang, Zhong Lin Wang and Rusen Yang
Micromachines 2024, 15(5), 645; https://doi.org/10.3390/mi15050645 - 13 May 2024
Abstract
The widespread vibration is one of the most promising energy sources for IoT and small sensors, and broad-frequency vibration energy harvesting is important. Triboelectric nanogenerators (TENGs) can convert vibration energy into electrical energy through triboelectricity and electrostatic induction, providing an effective solution to
[...] Read more.
The widespread vibration is one of the most promising energy sources for IoT and small sensors, and broad-frequency vibration energy harvesting is important. Triboelectric nanogenerators (TENGs) can convert vibration energy into electrical energy through triboelectricity and electrostatic induction, providing an effective solution to the collection of broad-frequency vibration energy. Also, the power supply in constrained and compact spaces has been a long-standing challenge. Here, a miniaturized power supply (MPS) based on a broad-frequency vibration-driven triboelectric nanogenerator (TENG) is developed. The size of the MPS is 38 mm × 26 mm × 20 mm, which can adapt to most space-limited environments. The TENG device is optimized through theoretical mechanical modeling for the external stimuli, it can efficiently harvest vibrational energy in the frequency range of 1–100 Hz and has a high output power density of 134.11 W/cm3. The developed device demonstrates its practical application potential in powering small electronics like LEDs, watches, and timers.
Full article
(This article belongs to the Special Issue Emerging Applications of Triboelectric Effects/Materials)
►▼
Show Figures
Figure 1
Open AccessCommunication
A High-Energy, Wide-Spectrum, Spatiotemporal Mode-Locked Fiber Laser
by
Boyuan Ge, Yajun Lou, Silin Guo, Yue Cai and Xinhai Zhang
Micromachines 2024, 15(5), 644; https://doi.org/10.3390/mi15050644 - 12 May 2024
Abstract
In this article, we demonstrate a high-energy, wide-spectrum, spatiotemporal mode-locked (STML) fiber laser. Unlike traditional single-mode fiber lasers, STML fiber lasers theoretically enable mode-locking with various combinations of transverse modes. The laser can deliver two different STML pulse sequences with different pulse widths,
[...] Read more.
In this article, we demonstrate a high-energy, wide-spectrum, spatiotemporal mode-locked (STML) fiber laser. Unlike traditional single-mode fiber lasers, STML fiber lasers theoretically enable mode-locking with various combinations of transverse modes. The laser can deliver two different STML pulse sequences with different pulse widths, spectra and beam profiles, due to the different compositions of transverse modes in the output pulses. Moreover, we achieve a wide-spectrum pulsed output with a single-pulse energy of up to 116 nJ, by weakening the spectral filtering and utilizing self-cleaning. Strong spatial and spectral filtering are usually thought to be necessary for achieving STML. Our experiment verifies the necessity of spatial filtering for achieving STML, and we show that weakening unnecessary spectral filtering provides an effective way to increase the pulse energy and spectrum width of mode-locked fiber lasers.
Full article
(This article belongs to the Special Issue Fiber Lasers and Applications)
►▼
Show Figures
Figure 1
Open AccessEditorial
Editorial for the Special Issue on Advanced Interconnect and Packaging, 2nd Edition
by
Dawei Wang and Wensheng Zhao
Micromachines 2024, 15(5), 643; https://doi.org/10.3390/mi15050643 - 11 May 2024
Abstract
Interconnect and packaging technologies are crucial aspects of modern electronics, and they are essential to achieve high performance, miniaturization and low power consumption of electronic equipment [...]
Full article
(This article belongs to the Special Issue Advanced Interconnect and Packaging, 2nd Edition)
Journal Menu
► ▼ Journal Menu-
- Micromachines Home
- Aims & Scope
- Editorial Board
- Reviewer Board
- Topical Advisory Panel
- Instructions for Authors
- Special Issues
- Topics
- Sections & Collections
- Article Processing Charge
- Indexing & Archiving
- Editor’s Choice Articles
- Most Cited & Viewed
- Journal Statistics
- Journal History
- Journal Awards
- Conferences
- Editorial Office
Journal Browser
► ▼ Journal BrowserHighly Accessed Articles
Latest Books
E-Mail Alert
News
Topics
Topic in
Bioengineering, JMMP, Materials, Micromachines, Polymers
Advances in Filament Engineering for Biomaterials
Topic Editors: Ming-Wei Chang, Zeeshan Ahmad, Hui-Min David WangDeadline: 30 June 2024
Topic in
Automation, Electronics, Eng, Hardware, Micromachines, Signals
New Development for Circuit Design: Synthesis, Modeling, Simulation, and Applications
Topic Editors: Nestor Evmorfopoulos, Alkiviadis Hatzopoulos, George I. StamoulisDeadline: 5 October 2024
Topic in
Applied Sciences, Electronics, Fluids, Micromachines, Processes, Inventions
Micro-Mechatronic Engineering
Topic Editors: Teng Zhou, Antonio F. MiguelDeadline: 31 October 2024
Topic in
Chemistry, Materials, Micromachines, Molecules, Photonics
Materials, Structure Designs and Device Fabrications for Highly Efficient/Long Lifetime Organic Light-Emitting Diodes
Topic Editors: Ping Chen, Jwo-Huei JouDeadline: 31 December 2024
Conferences
Special Issues
Special Issue in
Micromachines
Stereolithography (SLA) and Digital Light Processing (DLP) for Flexible and Sustainable Micro-Manufacturing
Guest Editors: Lara Rebaioli, Irene FassiDeadline: 20 May 2024
Special Issue in
Micromachines
Electron Microscopy and Single Molecule Studies of Biomolecular Structure and Dynamics
Guest Editor: Arkadiusz KulczykDeadline: 30 May 2024
Special Issue in
Micromachines
High-Quality Surface Integrity of Ultra-Precision Machining
Guest Editors: Kangsen Li, Huapan Xiao, Changlin Liu, Xiaoliang Liang, Yanbin ZhangDeadline: 15 June 2024
Special Issue in
Micromachines
Energy Storage Devices in Italy
Guest Editors: Andrea Lamberti, Pietro ZaccagniniDeadline: 30 June 2024
Topical Collections
Topical Collection in
Micromachines
Micromixers: Analysis, Design and Fabrication
Collection Editor: Kwang-Yong Kim
Topical Collection in
Micromachines
Piezoelectric Transducers: Materials, Devices and Applications
Collection Editor: Jose Luis Sanchez-Rojas
Topical Collection in
Micromachines
Micro/Nanoscale Electrokinetics
Collection Editor: Xiangchun Xuan